315393 - AE.30.2,5.P.VA.-
Art.nr: F402200016
Eaton AE.30 Series Electrical Clogging Indicator
Electrical Differential Pressure Indicator | 2.5 bar
The Eaton AE.30 series is a highly reliable electrical differential pressure clogging indicator, designed for Eaton (formerly Internormen) hydraulic and lubrication filter housings.
Productbeschrijving
Eaton AE.30 Series Electrical Clogging Indicator
Electrical Differential Pressure Indicator | 2.5 bar
The Eaton AE.30 series is a highly reliable electrical differential pressure clogging indicator, designed for Eaton (formerly Internormen) hydraulic and lubrication filter housings.
It is available with switching points from 0.6 to 5.0 bar and supports maximum operating pressures up to 420 bar (stainless steel version).
Equipped with an integrated electrical switch contact, the AE.30 provides a precise signal to trigger alarms or initiate automated machine protection sequences, ensuring timely filter element replacement and system protection.
• Model Code: AE.30.2,5.P.VA.-
• Part Number: 315393
Key Features
• Type: Electrical differential pressure indicator
• Δp switching points: 2.5 bar (36 psi) nominal
• Housing material: Heavy-duty Stainless Steel (VA)
• Maximum operating pressure: 420 bar (6000 psi)
• Maximum differential pressure: 160 bar (2320 psi)
• Electrical specifications: Up to 175 V DC (10 W) / 125 V AC (20 VA), max 0.5 A
• Electrical connection: DIN EN 175301‑803‑A plug (ISO 4400)
• Housing material options:
Aluminum or heavy‑duty stainless steel (VA)
• Seal materials: NBR (Nitrile) standard sealing)
• Protection class: IP65 according to DIN EN 60529
• Optional design:
Integrated hydraulic damper for protection against pressure spikes
✅ Operating Principle & System Protection
The AE.30 continuously monitors the differential pressure (Δp) between inlet (p₁) and outlet (p₂) of the filter.
As contamination builds up, differential pressure increases. Once the predefined switching point (Δp) is reached, the electrical contact is activated, enabling:
• Remote alarm signaling
• Integration into PLC or machine control systems
• Preventive maintenance planning
Protection Against Critical System FailuresContinuous monitoring helps prevent:
• Bypass valve activation: Avoids circulation of unfiltered, contaminated oil
• Filter element collapse: Protects the filter media from structural failure due to excessive differential pressure
✔ Ensures optimized component lifetime, stable filtration performance, and consistent fluid cleanliness
System Integration & Maintenance
The AE.30 features a maintenance‑free, threaded design for direct installation into compatible Eaton filter housings.
Installation and handling must be carried out in accordance with the official Eaton documentation.
Extended Monitoring Solutions
Looking for a different contamination monitoring setup? The broader Eaton portfolio offers solutions for every application:
• Visual Indicators – O / AOR / AOC series for local, purely visual inspection
• Combined visual/electrical indicators – OE / OP / AE.70 / AE.80 / AE.90 series
• Electronic sensors – VS5 / VS6 series for continuous monitoring
• Explosion‑proof versions – AE.10‑Ex series for hazardous environments
• Safety‑critical options – Redundant contact versions for high‑reliability systems
Request Support or Quote
➡️ Contact Fluidtech for expert advice or a fast quotation for your clogging indicators, filtration monitoring systems, or complete filter assemblies or complete Eaton filter solutions.